Skip to content

Electrical systems and substations

Installation and maintenance of medium- and low-voltage substations, overhead and underground distribution networks, and industrial and commercial electrical installations, including grounding, lightning protection and protection coordination as the project requires.

Two distribution panels wired and protected

Reference standards

NOM-001-SEDE
Electrical installations
NOM-029-STPS
Electrical installation maintenance
NMX-J-549
Lightning protection systems
CFE
Utility service and metering requirements

Executed work

  • Electrical room with main switchboards and a dry-type transformer
    Fig. 01Electrical room with main switchboards and a dry-type transformer
  • Overhead distribution pole with cutouts and sectionalizing equipment
    Fig. 02Overhead distribution pole with cutouts and sectionalizing equipment
  • Panels and electrical conduit installed outdoors
    Fig. 03Panels and electrical conduit installed outdoors

Service scope

  1. 01

    Medium- and low-voltage substations

    Installation and maintenance of compact and pad-mounted substations.

  2. 02

    Overhead and underground distribution

    Routing, conduit and cable tray, connection and commissioning of distribution networks.

  3. 03

    Industrial and commercial installations

    Service entrances, switchboards, power, lighting, conduit and cable tray, including classified areas per the site classification.

  4. 04

    Grounding and lightning protection

    Grounding systems, resistance measurement and lightning protection.

  5. 05

    Protection coordination

    Short-circuit study and protective device settings, subject to the requirement and the data available.

  6. 06

    Transformer sale and rental

    Supply for sale or rental, sized from the load study for the project.

Installations that can be verified

What you receive at close-out

  • Single-line diagram of the installed work
  • Design calculations where the project requires them
  • Functional test and commissioning report

Electrical work is executed to NOM-001-SEDE and to the utility requirements that apply to the project.

  • Execution to NOM-001-SEDE
  • Utility requirements applied where relevant
  • Short-circuit study and protection settings, where the installation calls for them
  • Verification through an authorized UVIE where the project requires it
  • Functional testing before energizing

Get a quote for the work you need

Tell us the equipment, the location and the type of intervention. We review the information to prepare the quotation or to ask for what is missing.